| 品牌:Dynisco丹尼斯科 | | 型号:14804100 | | 加工定制:是 | |
| 外形尺寸:96*96 mm | | 重量:0.5 ㎏ | | 用途:显示 | |
1480 1/8 DIN
Panel Indicator
Specifications
PERFORMANCE CHARACTERISTICS
Output Configuration 1 or 2 relay outputs, with optional linear
retransmission
Alarms 2 process high / low with adjustable hysteresis
Viewable Values Process variable, maximum value, minimum value
Legends °C/°F LED
Human Interface 3 button operation, 4 digit 13mm high display
red, green or red/green (color change on alarm),
plus 1 set-up, 2 alarm indicator
Input Thermocouple J, K, C, R, S, T, B, L, N
RTD 3 Wire PT100, 50Ω per lead maximum (balanced)
Strain Gauge 350 Ohm Strain Gage
Bridge Connection: 4 or 6 wire (6 to use internal shunt cal switch)
Bridge Excitation: 10 V +/- 7%
Bridge Sensitivity: 1.4 - 4 mV/V
Input Signal Span: - 25% to +125% of full scale (approximately -10
mV to +50 mV) Calibration switch between CAL2
& CAL1 terminals
Shunt Value: From 40% to 100%
Display Scaleable 1999 to 9999, with adjustable decimal point
DC Linear 0 to 20mA, 4 to 20mA, 0-50mV, 10-50mV, 0 to 5V,
1 to 5V, 0 to 10V, 2 to 10V
Note: 24V external power supply required
Input Impedance >10MΩ for thermocouple and mV ranges,
47KΩ for V ranges and 5Ω for mA ranges
Accuracy ±0.1% of input range ±1 LSD
(T/C CJC better than 1°C)
Sampling 4 per second, 14 bit resolution approximately
(250ms sample time)
PERFORMANCE CHARACTERISTICS (continued)
Sensor Break Detection <2 seconds (except zero based DC ranges), high
alarms activate for T/C RTD, Strain Gauge and mV
ranges, low alarms activate for mA or V ranges
OUTPUTS & OPTIONS
Alarm Relays Contacts Single Relay SPDT 2 Amp resistive at 240V
AC, >500,000 operations. Latching or non-latching.
Dual Relay SPST 2 Amp resistive at 240V >200,000
operations. Reinforced safety isolation from inputs
and other outputs
DC LINEAR RETRANSMIT
Outputs 0 to 20mA, 4 to 20mA into 500Ω max, 0 to 10V,
2 to 10V, 0 to 5V into 500Ω min.
Accuracy ±0.25% at 250Ω (degrades linearly to
0.5% for increasing burden to specified limits)
Logic Input External reset of latched relay, stored alarm 1
elapsed time, stored min/max PV values or initiate
tare function. Action occurs on high (3 to 5VDC)
to low <0.8VDC, or Open to Closed transition
OPERATING & ENVIRONMENTAL
Temperature & RH 0 to 55°C (-20 to 80°C storage), 20% to 95% RH
non-condensing
Power Supply 85 to 264V 50/60Hz 7.5VA (optional 20 to 48V AC
7.5VA/22 to 65V DC 5 watts)
Front Panel Protection IEC IP66 (Behind panel protection is IP20)
Standards CE. Pollution Degree 2, Installation Category II